1. See if the oil level of air pressure is above 3 parts 2 when loading, be sure to look at it when loading. If the oil level is not accurate when unloading in the shutdown, because there is no oil in the pipeline, the oil is returned to the oil and gas barrel. (Less air compressor oil)
2. Check the air compressor air filter. See if the air filter is blocked, if a lot of ash take the air gun to blow from the inside out. Blow it out. (air filter blockage)
If it's air-cooled, take the air gun and fan the heater. Fan heater clogging will cause the oil to pass through the fan heater without waiting for cooling, and the oil temperature is high, and the air compressor temperature will be high. (Cooler blocked)
If the above methods have no effect, it is the parts of the problem;
Parts problems:
1. (oil filter plug) the solid oil can not be cooled by the fan heater, and the machine temperature is high. Replace the oil filter.
2. (temperature control valve failure) Temperature control valve function: When the air compressor is started, the oil temperature is very low, the temperature control valve is closed, the oil can not be cooled through the fan heater "The temperature of the air compressor can not be lower than 75 degrees for a long time, below which there will be a lot of condensate, condensate more automatic drainage valve, drainage is not urgent, condensate water will be mixed with oil to lubricate the bearing, think about the water to lubricate the bearing, the bearing will change what I will not say", When the temperature of the air compressor is above 80 degrees, the temperature control valve will automatically open and the oil will be cooled by the fan heater, and the temperature will drop. (Replace the temperature control valve)