The cause of the pressure failure of the air compressor storage tank is unknown to many air compressor users. Mengma Filter has made an analysis of the cause of the pressure failure of the air compressor storage tank for some customers:
First, the air compressor storage tank pressure is too low fault phenomenon and possible causes:
1. There are a lot of leaks in the working pipeline of air compressor accessories. Check the leakage of the working pipe of the air compressor accessories with soapy water.
2. The intake valve is not fully opened. Press the "intake valve does not open or close according to air requirements" section to check the fault.
3, the air filter is blocked. Clean or replace the air filter.
4. The setting of the capacitive valve is incorrect. Adjust the capacitance valve to obtain the desired adjustment range.
5. The pressure gauge of the air compressor storage tank is damaged. Check the cause, if damaged, please replace.
6, the air demand is too large. Re-estimate requirements and add one more machine if necessary.