(1) Poor environmental ventilation and heat dissipation. There are three main situations in which the environment around the air compressor affects the heat dissipation: first, it is too close to the wall type obstacles; Second, there are other heat sources near the air compressor, and third, the front door and side door are open when running, and the fan cannot form strong airflow. This kind of situation can be made from the radiator to make a exhaust pipe connected to the outside.

(2) The radiator is blocked. When there is a lot of dust around the air compressor, long-term operation causes the radiator to adhere to a layer of dust or sludge, and the internal copper pipe is also easy to be blocked by the accumulation of oil dirt, thus affecting the heat dissipation effect.

(3) Oil filter is too dirty. When the oil filter is too dirty, the resistance oil can not enter the compressor according to the normal flow rate, and the compressor will quickly heat up due to the insufficient cooling oil. When the inlet and outlet oil pressure difference exceeds 0.18MPa, the filter element needs to be replaced.

(4) The cooling oil level is too low. When the cooler is inspected, the oil level should be supplemented immediately when it is lower than the lower end of the inspection tube.

(5) Low oil label or poor oil quality. Air compressor should use the manufacturer's special compressor oil, with other low grade or inferior oil will return viscosity and specific heat can not reach the standard resulting in high temperature.

(6) The fan tape is broken or loose. When the tape breaks, the press will automatically stop for about 5 minutes because the temperature is too high. If the tape is too loose, it will slip, reducing the fan speed and affecting the heat dissipation. At this time, the tightness of the fan tape should be replaced or adjusted.

(7) Oil cut-off valve failure. There is an oil cut-off valve between the oil filter and the compressor. When the oil cut-off valve cannot be opened, the temperature rises rapidly after the compressor is started because of no oil lubrication and cooling, and it will automatically stop for about 1min. Remove the temperature plug at the exhaust end of the compressor host, you will find that the plug is dry without oil, and there will be smoke floating out of the hole. Open the manhole at the bottom of the air compressor, remove the oil valve, and gently flick the valve stem with your finger to see whether it can be pushed forward and back and whether it can be easily reset. If the toggle or return is difficult, it is necessary to further disassemble the oil cut-off valve. If the stem or valve hole has grease, it should be polished with fine sandpaper until it can slide easily. If the spring is broken or there is a foreign body card will also affect the movement of the valve stem, at this time need to replace the spring or clean the spring and spring seat.