(1) The motor should be started separately to check if the direction of rotation is correct.
(2) After the motor is connected to the compressor, the number of turns of the disk should be flexible and free of blockage.
(3) The compressor should be started for 2-3 minutes, and after confirming that there is no abnormality, continuous operation is not less than 30 minutes.
(4) Continuous operation of air compressor vibration and bearing temperature should be normal, bearing temperature does not exceed 70 ° C, body temperature does not exceed 65 ° C; vibration intensity should not exceed 7.1 mm / s.
(5) The oil mirror is clear, the oil level line is clear, the oil level is normal, the oil quality is good, and the bearing has no oil leakage or oil simmering phenomenon.
(6) After the transfer test, the test results and the problems found during the inspection will be recorded in detail.