What happens when the minimum pressure valve fails to close?

Feb 21, 2025 Leave a message

There are three reasons for the failure of the minimum pressure valve to close. The analysis is as follows.

1. After the machine starts, the oil groove cannot rise, causing the air compressor to fail to load.

2. The oil content of outlet air increases.

3. The on-site air will pour back into the machine, resulting in the oil tank pressure can not fall when the car is empty and the air compressor injection after parking. Remove the minimum pressure check valve and replace it with a new one if it fails.