Atlas air compressor in the use of the process, the air compressor will run oil, the reasons for this phenomenon have many aspects. Mengma filter professional technical engineers to explain the analysis for you as follows:
1) The oil level is too high and too much oil is injected.
2) The return pipe is blocked.
3) The return tubing installation does not meet the requirements (distance from the bottom part of the oil separation core).
4) The exhaust pressure of the unit is too low during operation.
5) The internal partition of separation cylinder is damaged.
6) Oil leakage occurs in the unit.
7) Incorrect oil, resulting in a lot of foam.
8) Oil deterioration or beyond the shelf life use.
9) If the core pipe O-ring is not sealed, the oil will run away.
10) If the unit has an oil return check valve, the check valve out of control will cause the unit to shut down, the oil will flow back to the oil, and the oil will run when it is started again.
11) Damage and rupture of oil core.