Compressed air is an environmentally friendly power source commonly used in industry and is widely used in many fields such as industry, agriculture, commerce, national defense and science and technology.
Let's explore the real reasons behind the high energy consumption of traditional air compressor stations.
First, improper selection of air compressor
The demand for gas in all walks of life is different, and the performance requirements for air compressors are also different. Some enterprises in the purchase of air compressors overemphasize the investment of equipment, the performance indicators and energy consumption indicators of air compressors, while ignoring the accurate evaluation of their own gas characteristics, resulting in improper selection of final equipment, there may be equipment exhaust pressure and exhaust volume is too large, and the actual use does not match. Resulting in a large margin, reduce the operating efficiency of the equipment, there is a large waste of resources.
According to the US Department of Energy's survey of the compressor load percentage of compressed air enterprises worldwide, the load rate of China's air compressor is only 66%, far lower than the world average level, which shows that China's air compressor equipment utilization rate is still low, there is a lot of room for improvement.
Second, the equipment control mode is backward
The traditional air compressor station generally adopts manual on-duty control, and the start and stop of the air compressor need to be adjusted at any time according to the production demand. According to the production scheduling demand, the workers carry out the corresponding start and stop operation of the air compressor.
1. High energy consumption during unloading
When the air compressor equipment is loaded and running, the equipment starts to produce a large impulse current, which not only poses a threat to the safe and stable operation of the power grid, but also causes a serious waste of resources. When the compressor equipment is unloaded, the compressor motor is still in the running state, and the equipment is in no-load operation. For the air compressor under the traditional regulation mode, the energy consumption under no-load operation is more than 20% of the energy consumption under full load operation of the equipment, and the energy consumption of some air compressors can reach 40%, the energy consumption accounts for 9% to 18% of the total energy consumption, and the waste of power resources is serious.
2, climbing energy consumption is high
The loading and unloading control mode makes the pressure of the compressed gas run between the lowest working pressure value (that is, the lowest pressure to ensure the normal work of the user - the loading pressure) and the highest working pressure (the unloading pressure). The pressure difference is generally above 1bar. Through theoretical calculation and practical testing, it is learned that the energy consumption of the air compressor increases by 4 ~ 8% for every 1 kg increase in pressure.
3. Unreasonable station building design and management

1. Unreasonable pipeline design
Before the air compressor exhaust reaches the end, it needs to pass through coolers, dryers, filters, control valves and transmission pipes, etc. During the transmission process, the exhaust pressure is damaged due to the improper design of the pipe diameter, pipe head and pipe length, etc. Each loss of exhaust pressure of 1bar will cause an additional loss of 7.5% of the corresponding electric energy. Therefore, the optimization of the pipe network can further reduce the energy consumption of the air compressor station system.
2. Compressed gas leakage
Compressed gas leakage is a major hidden danger of air compressor station. The working environment of equipment in air compressor station is complex, and the maintenance workload of equipment is large. The pipe network of air compressor station has problems such as holes, aging or loosening of seals, etc. If not repaired in time, the compressed gas leakage of pipe network will be aggravated and the energy efficiency loss of air compressor station will be increased. According to statistics, the compressed gas leakage of the air compressor station accounts for about 20% to 25% of the total compressed gas production, and the loss is amazing. Reducing the compressed gas leakage is also an important means to improve the energy saving efficiency of the air compressor station.
3, waste heat waste
According to the testing results of the authority, the compressed air consumption of air compressor is only 10% of the total power consumption, and the remaining 90% of the power consumption is converted into heat energy, but in most enterprises, the heat generated by compressed air can not be fully utilized, and there is a more serious waste heat waste phenomenon, due to the temperature requirements of equipment operation. The oil and gas mixed steam caused by the high heat generated by the compressed air will be discharged into the atmosphere through the heat dissipation system of the air compressor as "waste heat", and the temperature of this part of the "waste heat" is usually between 80 ° C and 100 ° C, and the power consumed by the production of these "waste gases" accounts for about 25% to 30% of the input power of the air compressor. The waste heat of air compressor is also one of the reasons for the high energy consumption of air compressor station.