The compressor runs normally, but it is difficult to start after stopping

Mar 23, 2022 Leave a message

A, the use of oil grade is not correct or the use of mixed oil should be cleaned after a thorough oil change。

B, oily sticky, coking should be cleaned after a thorough oil change。

C. Serious air leakage of shaft seal shall be removed and replaced。

D. The original position of unloading valve disc changes and readjust。