1. Compressed air use.
2. Minimum service pressure.
3. Demand air volume at tip and off peak. If the difference between the highest and lowest used pressure is up to 3bar, it is necessary to consider the "high and low pressure split", and then choose different models of air compressors according to the burden change of the tip and the peak, such as the use of centrifugal (single machine >75CMM) or screw for "base load"
Rotary type (single machine <60CMM) : "Variable load" can be adjusted by using high pressure air compressor and large air storage barrel.
4. Different forms and grades of dryers and precision filters are selected and configured according to different gas quality. Too good quality wastes energy, and insufficient quality affects the process, which must be carefully considered.
5. The control technology of air compressor changes with each day. The technology of "multi-machine chain", "frequency conversion" and "remote monitoring" can effectively inhibit the waste of centrifugal BOV and spiral empty car (saving electricity bill by 25-40%), reduce the capacity and investment of standby machine (15-30%), and be stable
Air supply pressure (plus or minus 0.1bar).
6. Operating efficiency SHOULD NOT only compare NOMINAL horsepower and air volume on the catalog, but focus on the actual "performance curve" and "air volume per horse".
7. The installation takes into account the size of the room space, ventilation conditions, noise isolation, waste heat, waste water recovery and so on, all lead to the use of energy. In addition, "centralized" has lower installation, maintenance, and control costs than "distributed" and can also reduce peripherals. Air compressor (17 sheets)
8. As for the cooling method, there are two kinds of air cooling and water cooling, air cooling is not necessary to extra investment in cooling tower rainwater, but there must be good ventilation: water cooling is the operating temperature is not affected by the environment, favorable to the life of the air compressor, only icing burst and blocking shortcomings.
9. The stability of the planned voltage demand and voltage drop of the power supply must be required. The centrifuge is usually of high voltage and cannot move at all. It will impact the power grid when started and should be kept in regular operation.
10. The equipment room must be equipped with proper maintenance space, necessary lifting facilities, and access channels. The engineering personnel and maintenance personnel should also be trained in different maintenance professions.