Maintenance should be carried out after the air compressor is shut down and corresponding safety measures are taken.
Small air compressor adopts rotary oil separator, its maintenance method is the same as the oil filter;
The built-in steps are as follows:
(1) Loose the pipeline on the oil and gas separation cylinder, and at the same time, remove the pipeline from the outlet of the pressure maintenance valve to the rear cooler, and remember to ensure that it can be reinstalled correctly.
(2) loosen and take out the return oil pipe.
(3) Loosen the fastening bolt of the upper cover of the oil and gas barrel and remove the upper cover of the oil and gas barrel.
(4) take out the filter element of the fine oil separator and replace the new filter element and gasket of the fine oil separator.
(5) Reassemble according to the reverse steps and tighten the bolts with a torque wrench.
(6) After the machine starts up, re-tighten the cover bolt of the oil and gas separation barrel
(7) Check that the differential pressure switch equipped with oil fine separation on the oil and gas separation barrel is installed normally, and the pre-set value is 100kPa.