Air piping piping matters needing attention

May 20, 2021 Leave a message

Analysis of Chinese filter manufacturers - Mengma Filters is as follows:

(1) when piping in the main road, the pipeline must have a 1° ~ 2° inclination to facilitate the discharge of condensate water in the pipeline.

(2) the pressure drop of the pipe line shall not exceed 5% of the set pressure of the air compressor, so it is best to choose a larger pipe diameter when piping.

(3) the branch line must be connected from the top of the main road to avoid the flow of the condensate in the pipeline to the gas equipment. The air outlet line of the air compressor had better have a one-way valve.

(4) several air compressors are installed in series, and ball valves or automatic drainage valves must be installed at the end of the main road to facilitate the discharge of condensed water.

(5) the main road do not arbitrarily shrink, if you must shrink or enlarge the pipeline must use the tapering pipe, otherwise there will be mixed flow at the junction, resulting in large pressure loss, but also affect the service life of the pipeline.

(6) if the air compressor has gas storage tank and dryer and other purification buffer facilities, the ideal pipe should be screw air compressor + gas storage tank + filter + dryer + filter + fine filter.

In this way, some of the condensate can be filtered out of the tank,

At the same time, the gas storage tank also has the function of reducing the gas exhaust temperature.

The lower temperature and less water content of the air into the dryer, can reduce the load of the dryer or filter.

(7) if the air consumption of the system is very large and the time is very short, and the instantaneous air consumption changes greatly, it is advisable to add a gas storage tank as a buffer (its capacity should be greater than or equal to 20% of the maximum instantaneous air volume), which can reduce the frequency of frequent loading or unloading of the air compressor.

Reducing the number of action of the control element is of great benefit to maintaining the operation reliability of the air compressor.

In general, you can choose the capacity of 20% of the exhaust gas storage tank.

(8) For the compressed air with the system pressure below 1.5MPa, the flow rate in the conveying pipe shall be below 15m/ SEC to avoid excessive pressure drop.

(9) minimize the use of elbows and all kinds of valves in the pipeline to reduce pressure loss.

(10) The ideal piping is the main line around the entire plant, so that the compressed air on both sides can be obtained at any location.

For example, the pressure drop can be reduced when the gas consumption of a branch increases suddenly.

And in the ring main line is configured with appropriate valves, so as to repair and cut off.