1. The motor temperature controller is faulty, replace the temperature controller;
2. Overload protector fails, replace overload protector;
3. Air inlet is blocked, clean and maintain the air inlet;
4. The tension of the transmission belt is too tight, relax the transmission belt, the normal tension is the downward pressure distance of 0.8-1.0cm;
5. The air filter is blocked, replace the air filter (when the vacuum value is greater than 5psi);
6. If the starter contact is not good, maintain the starter contact;
7. The oil and gas separator is blocked, replace the oil and gas separator (when the pressure difference is greater than 0.8-1kg);
8. Motor bearing is not refueled, motor bearing is filled with butter;
9. If the ambient temperature is too high, install air duct exhaust equipment;
10. Three-phase voltage instability, underphase, voltage is too low (less than 10%), it is recommended to improve the power system;
11. The motor bearing is damaged, remove the motor to do insulation strengthening treatment;
12. Motor insulation is poor, replace motor bearings;
13. The motor wiring is loose, lock the motor wiring again.